7000 Master Programming Mode
Page 2
Regeneration Day Override
Example: Regenerate every 7 days [A- -7]
Cancel Setting [AOFF] = Default
Regeneration Cycle Step Programming (1-5)
Example: 10 minute Backwash, in US Format, Downflow [1- 10]
60 minute Brine Draw/Slow Rinse, in US Format [2- 60]
5 minute 2
nd
Backwash in US Format [3- - 5]
10 minute Rapid Rinse in US Format [4- 10]
12 minute Brine Refill US format [5- 12]
NOTE: All Above Settings Are Shown in Factory Default
Settings Based on Downflow Regeneration Type
and US-1 Display Format.
Flow Meter Size
Example: 1-1/4" Turbine Meter, US [F-82] = Default
1-1/4" Turbine Meter, metric [F21.6]
Safety Factor
Example: 25% Safety Factor [cF25]
0% = No Safety Factor [cF-O] = Default
Line Frequency
Example: 60Hz Line Frequency [LF60] = Default
50Hz Line Frequency [LF50]
Exit the Master Programming Mode
NOTE: Valve Calculates Programming Changes [CALc] and
Returns to the Service Position/Time of Day.